- AVAILABLE IN A
VARIETY OF SOLENOID,
- PRESSURE PILOT &
BLEED PILOT MODELS
-
- ALLENAIR'S Field
Proven High Tensile Manganese Bronze Slider
against a hardcoated
- aluminum slider
base (both lapped flat within one light band)
help make this a rugged,
- long life,
bubble tight, high flow compact valve.
|
SINGLE SOLENOID PNEUMATIC VALVE
(MODEL 4VS FOR SINGLE VALVE)
A
maintained electrical contact is
required to hold the valve in
its shifted position. Breaking
the electrical contact will
return the valve to its original
position.
|
|
|
DOUBLE SOLENOID PNEUMATIC VALVE
(MODEL 4VD FOR SINGLE VALVE)
A
momentary or maintained
electrical contact applied to
one solenoid will shift the
valve. It will remain in that
position until the other
solenoid is energized, which
will cause the valve to shift to
its original position. If a
maintained contact is employed,
the first solenoid must be
de-energized before the other is
energized.
|
|
|
SINGLE AIR PILOT PNEUMATIC VALVE
(MODEL 4VPS FOR SINGLE VALE)
A
continuous pilot pressure
applied to the valve will hold
it in its shifted position. When
the pilot pressure is released
the valve will shift to its
original position. Pilot
pressure must be at least 25% of
the operating pressure. Minimum
operating pressure is 30 PSI.
|
|
|
DOUBLE AIR PILOT PNEUMATIC VALVE
(MODEL 4VPD FOR SINGLE VALVE)
A
momentary or maintained pilot
pressure applied to one side of
the valve will cause it to
shift. It will remain in that
position until a pilot pressure
is applied to the other side,
which will cause the valve to
return to its original position.
If a maintained pilot pressure
is employed, it must be released
before the other pilot pressure
is applied. Pilot pressure must
be at least 25% of the operating
pressure.
|
|
|
DOUBLE BLEED PILOT PNEUMATIC
VALVE (MODEL 4VBL FOR SINGLE
VALVE)
A
separate Bleeder Valve, such as
the Allenair BV100 or BV-1/8,
must be installed in a line to
each bleed port. Depressing one
Bleeder Valve momentarily will
shift the valve. It will remain
in that position until the other
Bleeder Valve is depressed,
which will cause the valve to
shift to its original position.
|
|